Back to Other Calculators
Liquid Extraction
Countercurrent solvent extraction design using distribution coefficients and the Kremser equation
Input Parameters
Partitioning
Higher K = better extraction
Design Results
2
Theoretical Stages
(1.7712 exact)
100.0000%
Recovery
20.0000 kg/h
Stream Properties
Extract Flow:500.0000 kg/h
Raffinate Flow:0.0000e+0 kg/h
Extract Composition:2.0000%
Extraction Factor (A):3.0000
Single Stage Comparison
Single stage would give: 2.5000% vs target 1.0000%
Design Recommendations
Good extraction factor — efficient separation